THERMAL IMAGING
If a Picture Can Say a Thousand Words then ..

Thermographic Imaging Pictures May Save Thousands of Dollars.

Thermal Imaging Inspection is a "Proactive Service" where faulty plant and equipment can be rectified under routine maintenance schedules without interruption to production processes. The Alternative is a "Reactive Service" where plant and equipment may fail without notice therefore being responsible for unnecessary production downtime.

Our Thermal Imaging Camera can be used for Electrical , Mechanical or any other process where temperature deviations can effect a process or outcome.

Electrical Measurements & Testing utilise an Indigo Systems TVS-620 thermal imaging camera and associated software to provide Thermal Imaging Inspection services to Tasmania Industry.

Some of the significant features of this instrument are :

Temperature Range : 20 deg C to 900 deg C (1100 deg C at reduced accuracy)
Measurement Accuracy : +/-2% or 2 deg C (typical)
Temperature Sensitivity : 0.15 deg C
Field of View : 26 deg (H) x 19 deg (V)
Camera Display : 125mm colour LCD Monitor
Minimum Focus Length : 30 cm
Imaging Recording : 48Mb PCMCIA card (240 x 12 bit images)


On Site Inspection
Back to Top^

EM&T staff complete on site Thermographic Image Inspections to meet the clients needs.

On site cooperation with plant maintenance staff is recommended to ensure all inspection points are addressed as well as gaining first hand knowledge of critical areas.

This sample image shows where a blockage in equipment at a paper mill has caused dangerous thinning of PVC tubes. This was not detectable by any other means and almost certainly saved costly failure and associated downtime.
The graph shows the temperature profile across the line between the arrows with sharp variations of only 1 degree C.
Monthly thermal inspection of this equipment is estimated to be now saving this client $100,000 annually in downtime reduction.


Reports
Back to Top^


Our thermal image inspection service includes a full color report which includes visible and infra-red images of the problem component. The report also provides details of actual v differential temperatures , electrical loads , component identification and repair recommendations.

Repair Priorities are identified as follows :-

  • Immediate Action Required

  • Urgent Action Required

  • Next Shut Down Period

  • Continue Monitoring

Accompanying the report is a list of all sites/areas inspected.

The link below is to a sample of our standard report which can be customised to suit the clients requirements and provided on CD if desired.


EMT operators have completed the University of Melbourne/RMIT (Centre for Manufacturing) course "Theory and Practice of Infrared Thermography for Condition Monitoring" and are accredited members of the Australian Institute for Non-Destructive Testing.



Thermal Imaging Services Contact Information
Back to Top^
Contacts

Alan Clark

Postal Address Electrical Measurements & Testing Pty Ltd
PO Box 280 Glenorchy Tas 7010
Email alan.clark@elecmeas.com.au
Telephone Telephone
(03) 62726133
0417 301 559
Fax (03) 62726671